Product Description
- 1.5 kVA 1350 W. 8 AC outlet(s).
- Sealed Lead Acid (VRLA).
- Black.
- SENTINEL DUAL is the high density version of the Premium Pro range of double-conversion on-line UPS..
- SENTINEL DUAL is designed to power critical loads such as servers, storage systems, telephone equipment, medical systems and industrial applications..
- The UPS is ideal for Blade servers with an input power factor close to Unity (1).
- The UPS has can be used as tower UPS or within a rackmount cabinet, and takes up only 2U in height..
- SENTINEL DUAL has a modern design, choice of functional formats, and represents the state-of-the-art technology from the Riello UPS research & development team.
- The UPS can achieve an on-line. operating efficiency of 92%..
- For critical business continuity applications requiring long runtimes, SENTINEL DUAL can be installed with battery extension packs (ER models) with their own internal battery chargers to maintain sensible recharge times..
- The UPS also incorporates the Riello UPS ‘power-off’ function found in other ECO Line UPS.
- Premium Dual is designed to save energy when no loads are connected..
- SIMPLIFIED INSTALLATION.
- Tower or Rackmount UPS: SENTINEL DUAL can be installed as tower or 19” rackmount UPS, with a front mimic panel that can be turned through 90º to suit the installation..
- Noise Free Operation (<40dBA): the UPS can be installed in any environment thanks to its PWM digitally-controlled high frequency inverter..
- High Temperature Operation: UPS components are sized for high temperature operation up to 40ºC and are not therefore stressed during normal operational environments..
- EnergyShare: Premium Dual output sockets can be programmed to disconnect less critical loads when the mains power fails..
- REDUCED MANAGEMENT COSTS.
- SENTINEL DUAL can be programmed remotely via software or set manually from the front mimic panel to operate in a range of energy saving operating modes:.
- On Line: maximum power protection and output voltage waveform quality.
- ECO: to increase operating efficiency to 98% and provide line interactive protection.
- Smart Active: with the UPS selecting automatically its operating mode
- ECO or On-Line dependent upon the reliability and quality of the local mains power supply..
- Backup: for emergencies only with the UPS only operating when mains power fails.
- Frequency converter: from 50 to 60Hz or 60 to 50Hz..
- ADVANCED COMMUNICATION.
- SENTINEL DUAL offers maximum flexibility for integrations with any communication system..
- Multiplatform communication for all operating systems and network environments, Powershield3 supervision and shut-down software included for Windows 7, 2008, Vista, 2003, XP, Linux, Mac OS X, Sun Solaris and VMware ESX operating systems and other Unix operating systems..
- UPS Tools configuration and personalisation software supplied as standard..
- RS232 serial port and opto-isolated contacts..
- USB port.
- Slot for communication cards such as Modbus/Jbus, TCP/IP, SNMP and relay contacts..
- HIGH OUTPUT VOLTAGE QUALITY.
- Even with distorting loads (IT loads with a crest factor of up to 3:1)..
- High short circuit current on bypass..
- High overload capacity: 150% from inverter (even with no mains power)..
- Filtered, stabilised, reliable (On Line double conversion technology (VFI in accordance with EN62040-2 class C2) standard with filters to suppress atmospheric disturbances..
- Load power factor correction: incoming UPS power factor close to 1 and sinusoidal current absorption..
- HIGH LEVELS OF BATTERY RELIABILITY.
- Automatic and manual battery tests.
- Batteries are ‘hot-swappable’ and user replaceable..
- Unlimited battery runtime extension using battery extension packs..
- OTHER
- .
- Output voltage can be selected using software (220-230-240V)..
- Auto-restart when mains power returns (programmed via software).
- Stand-by on Bypass: when the machine is switched off, it automatically goes into bypass operation with batteries charging..
- Power-Off with zero load connected to save energy.
- Low battery warning.
- Power-on delay.
- Full microprocessor control..
- Automatic bypass without interruption.
- Status, measurements and alarms available on the front panel mimic panel and LCD.
- UPS firmware upgrade via PC platform.
- Input protection including a user reset thermal switch (up to 1500VA).
- Back-feed protection.
- Manual option to switch to bypass..
- .
- Power protection
- .
- Over current, Over voltage, Overheating, Short circuit, Under voltage.
- Input power factor. 0.98.
- Efficiency. 98%.
- Surge energy rating. 300 J.
- Input frequency. 50/60 Hz.
- Input operation voltage (max). 276 V.
- Input operation voltage (min). 140 V.
- Output power. 1350 W.
- Output power capacity. 1.5 kVA.
- Ports & interfaces.
- RS-232 ports. 1.
- AC outlets quantity. 8 AC outlet(s).
- Power plug.
- C14 coupler.
- AC outlet types.
- C13 coupler.
- Battery.
- Battery recharge time. 4 h.
- Battery technology.
- Sealed Lead Acid (VRLA).
- Design.
- Display type.
- LCD.
- Built-in fan.
- Yes.
- Cooling type.
- Active.
- Product colour.
- Black.
- Operational conditions.
- Operating temperature (T-T). 0 - 40 °C.
- Weight & dimensions.
- Weight. 18 kg.
- Height. 450 mm.
- Depth. 425 mm.
- Width. 87 mm.
- Packaging data.
- Package weight. 21.5 kg.
- Other
- .
- Package dimensions (WxDxH). 550 x 600 x 245 mm
Specifications
| Delivery Time | 3-5 working days |
|---|---|
| Delivery Cost | £0.00 |
Affiliate Disclosure: We may earn a commission when you purchase through our links, at no extra cost to you. This helps support our independent reviews. Learn more